Gas Flow Unit Converter
Convert volumetric gas flow between sccm, slm, L/min, m³/h, CFM and MMSCFD. Enter a value, choose the units, then press Convert.
About the Gas Flow Unit Converter
Gas flow is only meaningful with a reference condition, because a gas expands and contracts with temperature and pressure. This converter treats every unit as a volumetric flow at standard conditions: 0 °C and 1 atm for the metric and sccm/slm units, and the conventional standard cubic foot for CFM and MMSCFD.
The core identity is simple: 1 sccm is 1 cm³/min, 1 slm is 1 L/min, and 1 m³/h is 16.667 L/min. CFM is 28.317 L/min at standard conditions. If your process is at a different temperature or pressure, convert to mass flow or correct the volume before comparing figures.
How the calculation works
- 1 sccm = 0.001 L/min; 1 slm = 1 L/min.
- 1 m³/h = 16.667 L/min; 1 m³/min = 1,000 L/min.
- 1 CFM = 28.3168 L/min at standard conditions.
- 1 MMSCFD = 19,664.5 L/min at standard conditions.
Reference values
| Flow unit | L/min | m³/h | CFM |
|---|---|---|---|
| 1 sccm | 0.001 | 0.00006 | 0.0000353 |
| 1 slm | 1 | 0.06 | 0.0353 |
| 1 m³/h | 16.667 | 1 | 0.5886 |
| 1 CFM | 28.317 | 1.699 | 1 |
| 1 MMSCFD | 19,664.5 | 1,179.9 | 694.4 |
Worked example: sccm, CFM and a real process
A 500 sccm mass-flow controller passes 0.5 L/min, or 0.03 m³/h, at standard conditions. A 100 CFM fan moves 2,831.7 L/min, about 169.9 m³/h. If the actual line is at 2 bar and 40 °C, the standard volumetric flow is lower than the actual flow; correct with the ideal-gas ratio before comparing the two readings.
The reference condition is the part that trips people up. This page uses 0 °C and 1 atm for the metric, sccm and slm units, and the conventional standard cubic foot for CFM and MMSCFD. Some industries use 15 °C or 20 °C instead. A flow quoted without its reference condition is incomplete, so record it alongside the number.
Frequently asked questions
Sources and standards
A volumetric gas flow is meaningless without its reference temperature and pressure. NIST OWM defines the SI and customary units used here, and the page distinguishes actual flow from the standard-condition figures used in gas billing.