🧪 Laboratory

Laboratory & Medical Units

Convert a laboratory result between the units used in different countries. Choose the analyte, enter the value and unit, then press Convert.

Written and reviewed by SM Arijul Islam · Last reviewed · Editorial standards · Report an error

About the Laboratory & Medical Units

Laboratory units are not interchangeable because the denominator differs: mass per volume (mg/dL), amount of substance per volume (mmol/L, µmol/L) and mass per volume in SI (g/L). Converting glucose from mg/dL to mmol/L divides by 18.02; cholesterol divides by 38.67; creatinine multiplies by 88.4 to reach µmol/L.

This converter covers the common analytes and reports the result in every unit used for that test. Reference ranges are included as orientation only. They vary by laboratory, method, age, sex and pregnancy, and a result should always be interpreted against the range printed on the report.

How the calculation works

  • Glucose: mg/dL ÷ 18.0182 = mmol/L.
  • Cholesterol: mg/dL ÷ 38.67 = mmol/L.
  • Creatinine: mg/dL × 88.4 = µmol/L.
  • Bilirubin: mg/dL × 17.1 = µmol/L.
  • Calcium: mg/dL ÷ 4.008 = mmol/L.

Reference values

Common laboratory conversions
AnalyteConventionalSIConversion
Glucosemg/dLmmol/L÷ 18.0182
Cholesterolmg/dLmmol/L÷ 38.67
Triglyceridesmg/dLmmol/L÷ 88.57
Creatininemg/dLµmol/L× 88.4
BUNmg/dLmmol/L÷ 2.8
Bilirubinmg/dLµmol/L× 17.1
Calciummg/dLmmol/L÷ 4.008
Hemoglobing/dLg/L× 10

Worked example: three common results

A glucose result of 90 mg/dL is 90 ÷ 18.0182 = 5.0 mmol/L. A cholesterol of 200 mg/dL is 5.17 mmol/L. A creatinine of 1.0 mg/dL is 88.4 µmol/L. These are unit conversions only; the reference range printed on your report is the one that matters.

Laboratories choose units by convention and discipline. SI units are standard in many European and international laboratories, while mg/dL remains common in the US. The underlying result is the same; only the unit and the reference interval change. Never compare a number across units without converting it first.

Frequently asked questions

Methods, calibrators and populations differ. A range is established for a particular assay and population, so use the range on your own report.
No. Conversion changes units, not the clinical meaning. Diagnosis depends on the test, the patient and the reference range.
It is the molar mass of cholesterol divided by 10, which turns mg/dL into mmol/L. Each analyte has its own factor.
Convention and journal style vary by country and discipline. SI units are standard in many international laboratories, while mg/dL remains common in the US. The result is the same; only the unit changes.

Sources and standards

Laboratory results are not interchangeable across countries: glucose may be reported in mg/dL or mmol/L, and the conversion depends on molar mass. Values here use IUPAC molar masses from the NIST CODATA compilation, and the page warns that reference ranges are assay-specific.

Related tools

Medical disclaimer

This tool is for general information and education only. It is not medical advice, a diagnosis or a treatment plan, and it is not a substitute for a qualified healthcare professional. Clinical values, doses and drip rates vary with the patient, the equipment and local protocol, so confirm them against the current standard or prescription and consult the clinician responsible for care.