Solar panel output: watts, area and sun hours

A solar panel is rated in watts, but the energy it delivers depends on where it is, how it is mounted and how hot it gets. Here is how to turn a nameplate rating into a realistic daily and annual figure.

Written and reviewed by SM Arijul Islam · Last reviewed · Editorial standards · Report an error

Nameplate watts are a laboratory number

Panel wattage is measured at standard test conditions (STC): 1,000 W/m² irradiance, 25 °C cell temperature, and an air mass of 1.5. A 400 W panel produces 400 W only in that laboratory flash test. In the field, irradiance varies through the day, cells run hotter than the air, and soiling, wiring and inverter losses take a share.

Use the nameplate as a comparison tool, not a promise. Two 400 W panels from different manufacturers can have different efficiency and different real-world output.

Efficiency is watts per area

Efficiency = rated power ÷ (1,000 W/m² × panel area) × 100. A 400 W panel with an area of 1.7 m² is 400 ÷ 1,700 = 23.5% efficient. That is the share of the sunlight falling on the panel that becomes DC electricity at STC.

Efficiency matters most when roof area is limited. A 22% panel costs more per watt but needs less roof for the same array. If you have plenty of area, a lower-efficiency panel can be the cheaper choice.

Typical panel sizes and efficiencies
PanelAreaEfficiencyWatts/m²
250 W1.6 m²15.6%156
300 W1.7 m²17.6%176
350 W1.8 m²19.4%194
400 W1.9 m²21.1%211
450 W2.0 m²22.5%225

The same wattage can come from different areas. A high-efficiency panel is not automatically a better investment; it depends on the cost per watt and the value of the roof space.

Peak sun hours

Peak sun hours (PSH) are the number of hours at 1,000 W/m² that would deliver the same daily irradiance. A location with 4.5 PSH receives about 4.5 kWh/m² per day. PSH fold latitude, season, clouds and haze into one number.

Daily energy (kWh) = array size (kW) × PSH × derate factor. A 4 kW array at 4.5 PSH and 0.8 derate produces 4 × 4.5 × 0.8 = 14.4 kWh/day on an average day. Annual energy is daily × 365, about 5,256 kWh.

That is an average. Winter days produce less and summer days more. Use monthly PSH data for a serious estimate, not a single annual figure.

Approximate annual-average peak sun hours
LocationPSH/day
London2.7
Berlin2.9
Tokyo3.4
Sydney4.3
Madrid4.8
São Paulo4.3
Mumbai5.0
Cape Town5.0
Dubai5.5
Phoenix5.8

These are rounded annual averages for a well-oriented, unshaded site. Local microclimate, tilt, shading and the data source can move them by 10–20%.

Derating: where the watts go

Typical losses in a grid-connected system
LossTypical rangeNotes
Temperature5–15%Cells run hotter than ambient
Inverter3–8%Conversion and standby losses
Wiring1–3%DC and AC resistance
Soiling2–5%Dust, pollen, bird droppings
Mismatch1–3%Panels not perfectly matched
Shading0–30%+Can be much worse than it looks
Availability1–2%Downtime and maintenance

A combined derate of 0.75–0.85 is a sensible quick estimate. Use 0.8 for a first pass, then replace it with a local design tool or PVWatts for a real installation.

Temperature

Cell temperature is usually 20–30 °C above ambient in full sun. A panel with a −0.35%/°C coefficient loses about 7–10% at 45–55 °C cell temperature versus 25 °C. That loss is already inside the derate factor if you use 0.8, so do not subtract it twice.

Cool, windy, open-rack mounting runs cooler than a flush roof mount. High-altitude sites run cooler but may have more irradiance.

Orientation, tilt and shading

North-facing panels in the northern hemisphere lose a lot of annual yield; east/west splits production across the day. Tilt near latitude is a common starting point for year-round output, but a steeper tilt favours winter and a shallower tilt favours summer.

Shading is not linear: a small shadow on one cell can disproportionately reduce a series string. Bypass diodes limit the damage but do not eliminate it. Keep panels clear of chimneys, trees and future obstructions.

What the numbers mean for a roof

To estimate array size, divide the available roof area by the panel area. A 20 m² roof with 2 m² panels fits 10 panels, about 4 kW at 400 W each, assuming no gaps for access or shading. Real layouts lose 10–20% to edges, walkways and setbacks.

Check the inverter limit and local grid rules. A 4 kW array with a 3.6 kW inverter is common; clipping losses are small in most climates but larger in very sunny, cool locations.

Quick checks

  • Use monthly peak sun hours, not a single summer figure.
  • Apply a derate of 0.75–0.85.
  • Do not double-count temperature loss.
  • Check shading at the worst time of year.
  • Use a local design tool for a real installation.

Frequently asked questions

At 4.5 peak sun hours and a 0.8 derate, about 1.44 kWh/day, or roughly 526 kWh/year. A sunnier site or a higher derate will produce more.
Only at the same irradiance and temperature. Area, efficiency, orientation, shading and the inverter all affect the delivered energy.
STC is 1,000 W/m², 25 °C cell temperature and AM1.5. NOCT is 800 W/m², 20 °C ambient, 1 m/s wind and open-rack mounting. NOCT is closer to real conditions but is still a standard.
Yes, at reduced output. Diffuse light still generates electricity, but output can fall to 10–30% of a clear-sky day.
No. PV output falls as cell temperature rises; the temperature coefficient is negative, typically −0.3 to −0.45% per °C.
About 18–22 m² of panel area for 400 W panels at 1.8–2.0 m² each. Leave extra space for access, setbacks and shading.

Sources

  • NREL PVWatts Calculator and documentation.
  • NREL National Solar Radiation Database (NSRDB).
  • IEC 61215 — design qualification and type approval of PV modules.
  • IEC 61724 — photovoltaic system performance monitoring.
  • Manufacturer datasheets for module dimensions, temperature coefficients and power tolerances.